{"id":766,"date":"2025-11-12T14:31:16","date_gmt":"2025-11-12T06:31:16","guid":{"rendered":"https:\/\/ksxiqian.cn\/?p=766"},"modified":"2026-06-01T09:49:02","modified_gmt":"2026-06-01T01:49:02","slug":"supply-siemens-plc-module-6es7193-6bp00-0da1-siemens-base-unit","status":"publish","type":"post","link":"https:\/\/ksxiqian.cn\/?p=766","title":{"rendered":"6ES7193-6BP00-0DA1 Siemens ET200SP Base Unit Supply"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\">Product Introduction<\/h3>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">We <strong>supply the Siemens 6ES7193-6BP00-0DA1<\/strong>, a compact <strong>BU15-P16+A0+2D\/T base unit<\/strong> (BU type A1) designed for the SIMATIC ET200SP distributed I\/O system. It offers reliable mechanical mounting and electrical connection for standard ET200SP I\/O modules, featuring push\u2011in terminals and integrated temperature acquisition.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Key Features<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-medium-font-size\"><strong>Model<\/strong>: 6ES7193-6BP00-0DA1 (BU15-P16+A0+2D\/T)<\/li>\n\n\n\n<li class=\"has-medium-font-size\"><strong>Type<\/strong>: A1 base unit, 15 mm slim width<\/li>\n\n\n\n<li class=\"has-medium-font-size\"><strong>Terminals<\/strong>: 16 push\u2011in terminals, no auxiliary terminals<\/li>\n\n\n\n<li class=\"has-medium-font-size\"><strong>Integrated temperature sensing<\/strong> for environmental monitoring<\/li>\n\n\n\n<li class=\"has-medium-font-size\"><strong>New load group<\/strong>, suitable for digital\/analog I\/O modules<\/li>\n\n\n\n<li class=\"has-medium-font-size\"><strong>IP20 protection<\/strong>, industrial grade, CE\/RoHS compliant<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Technical Specifications<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-medium-font-size\">Width \u00d7 Height: 15 mm \u00d7 117 mm<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Current capacity: max. 10 A total, 2 A per channel<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Operating temperature: -25 \u00b0C to +60 \u00b0C<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Mounting: DIN rail, vertical installation<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Compatibility: all ET200SP A1\u2011type I\/O modules<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Applications<\/h3>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">This base unit is widely used in <strong>machine building, process control, packaging lines, and factory automation<\/strong>, especially where <strong>narrow cabinet space<\/strong> and <strong>temperature monitoring<\/strong> are required. It enables flexible, space\u2011saving distributed I\/O configurations.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Our Supply Advantages<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-medium-font-size\"><strong>Genuine Siemens parts<\/strong>, factory new and sealed<\/li>\n\n\n\n<li class=\"has-medium-font-size\"><strong>Bulk supply &amp; competitive price<\/strong> for 6ES7 series<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Fast global shipping (DHL\/FedEx\/UPS)<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Professional technical support &amp; after\u2011sales service<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Product Introduction We supply the Sieme&hellip;<\/p>\n","protected":false},"author":1,"featured_media":767,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[24],"tags":[],"class_list":["post-766","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-et200"],"acf":[],"_links":{"self":[{"href":"https:\/\/ksxiqian.cn\/index.php?rest_route=\/wp\/v2\/posts\/766","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ksxiqian.cn\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ksxiqian.cn\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ksxiqian.cn\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ksxiqian.cn\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=766"}],"version-history":[{"count":2,"href":"https:\/\/ksxiqian.cn\/index.php?rest_route=\/wp\/v2\/posts\/766\/revisions"}],"predecessor-version":[{"id":8836,"href":"https:\/\/ksxiqian.cn\/index.php?rest_route=\/wp\/v2\/posts\/766\/revisions\/8836"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ksxiqian.cn\/index.php?rest_route=\/wp\/v2\/media\/767"}],"wp:attachment":[{"href":"https:\/\/ksxiqian.cn\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=766"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ksxiqian.cn\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=766"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ksxiqian.cn\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=766"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}