{"id":669,"date":"2025-11-10T21:19:07","date_gmt":"2025-11-10T13:19:07","guid":{"rendered":"https:\/\/ksxiqian.cn\/?p=669"},"modified":"2026-06-01T13:41:12","modified_gmt":"2026-06-01T05:41:12","slug":"spot-siemens-plc-module-6es7134-6gd01-0ba1-analog-input","status":"publish","type":"post","link":"https:\/\/ksxiqian.cn\/?p=669","title":{"rendered":"6ES7134-6GD01-0BA1 Siemens ET200SP AI 4xI 2\/4-wire Standard Analog Input Module"},"content":{"rendered":"\n<h4 class=\"wp-block-heading\">Core Product Info<\/h4>\n\n\n\n<ul class=\"wp-block-list has-medium-font-size\">\n<li><strong>Model<\/strong>: 6ES7134-6GD01-0BA1<\/li>\n\n\n\n<li><strong>Type<\/strong>: SIMATIC ET200SP <strong>AI 4xI 2\/4-wire ST<\/strong> (4-channel Standard Current Input)<\/li>\n\n\n\n<li><strong>Condition<\/strong>: New original Siemens, factory sealed, <strong>Germany origin (DE)<\/strong><\/li>\n\n\n\n<li><strong>System<\/strong>: ET200SP distributed I\/O (PROFINET\/PROFIBUS)<\/li>\n\n\n\n<li><strong>Function<\/strong>: 4\u2011channel differential current input for 2\/4\u2011wire transmitters<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">Key Features<\/h4>\n\n\n\n<ul class=\"wp-block-list has-medium-font-size\">\n<li><strong>4\u2011channel differential current input<\/strong>: Standard type for 2\/4\u2011wire sensors<\/li>\n\n\n\n<li><strong>Precision<\/strong>: <strong>16\u2011bit resolution (\u00b120 mA) \/ 15\u2011bit (4\u201320 mA)<\/strong>, <strong>\u00b10.3% FS basic error<\/strong><\/li>\n\n\n\n<li><strong>Signal ranges<\/strong>: 0\u201320 mA, 4\u201320 mA, \u00b120 mA (per\u2011channel configurable)<\/li>\n\n\n\n<li><strong>Speed<\/strong>: 400 \u00b5s\/channel; conversion time 50\/60\/180 ms selectable<\/li>\n\n\n\n<li><strong>Diagnostics<\/strong>: Channel\u2011level open\/short circuit, overload, LED indication<\/li>\n\n\n\n<li><strong>Isolation<\/strong>: 707 V DC between channels &amp; backplane bus<\/li>\n\n\n\n<li><strong>Base unit<\/strong>: BU type <strong>A0\/A1<\/strong>, color code <strong>CC03<\/strong> (push\u2011in terminals)<\/li>\n\n\n\n<li><strong>Software<\/strong>: TIA Portal \u2265 V14, STEP 7 \u2265 V5.6<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">Applications<\/h4>\n\n\n\n<ul class=\"wp-block-list has-medium-font-size\">\n<li><strong>Process control<\/strong>: Flow, pressure, level, temperature (4\u201320 mA\/\u00b120 mA transmitters)<\/li>\n\n\n\n<li><strong>Industrial automation<\/strong>: Chemical, water treatment, HVAC, packaging<\/li>\n\n\n\n<li><strong>High\u2011precision current loops<\/strong>: Critical measurements requiring \u00b10.3% accuracy<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">Supply &amp; Sales Advantages<\/h4>\n\n\n\n<ul class=\"wp-block-list has-medium-font-size\">\n<li>\u2705 <strong>Genuine Siemens, Germany origin, 2\u2011year warranty<\/strong><\/li>\n\n\n\n<li>\u2705 <strong>New factory sealed, spot stock, fast delivery (DHL\/FedEx)<\/strong><\/li>\n\n\n\n<li>\u2705 <strong>Competitive pricing &amp; bulk discount<\/strong><\/li>\n\n\n\n<li>\u2705 <strong>Full ET200SP series one\u2011stop supply<\/strong><\/li>\n\n\n\n<li>\u2705 <strong>Professional tech support &amp; after\u2011sales service<\/strong><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Core Product Info Key Features Applicati&hellip;<\/p>\n","protected":false},"author":1,"featured_media":614,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[24],"tags":[],"class_list":["post-669","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-et200"],"acf":[],"_links":{"self":[{"href":"https:\/\/ksxiqian.cn\/index.php?rest_route=\/wp\/v2\/posts\/669","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ksxiqian.cn\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ksxiqian.cn\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ksxiqian.cn\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ksxiqian.cn\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=669"}],"version-history":[{"count":2,"href":"https:\/\/ksxiqian.cn\/index.php?rest_route=\/wp\/v2\/posts\/669\/revisions"}],"predecessor-version":[{"id":8896,"href":"https:\/\/ksxiqian.cn\/index.php?rest_route=\/wp\/v2\/posts\/669\/revisions\/8896"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ksxiqian.cn\/index.php?rest_route=\/wp\/v2\/media\/614"}],"wp:attachment":[{"href":"https:\/\/ksxiqian.cn\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=669"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ksxiqian.cn\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=669"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ksxiqian.cn\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=669"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}